The weather station is capable of measuring and transmitting all key indicators necessary for the efficient operation of specialized services to the central computer:
• temperature and air humidity• direction, wind speed and gusting
• atmosphere pressure
• dew point temperature
• type and intensity of precipitation
• road surface temperature
• road temperature at depth
• amount of precipitation on the road surface
• presence of the reagents on the road surface
The basic meteorological station consists of the following components:
• Station controller• Air temperature and humidity sensor
• Precipitation sensor
• Wind direction and speed sensor
• Ground surface temperature sensor
• Surface condition sensor
• Atmospheric pressure sensor
Road Visibility Sensor

Property | Description/Value |
Sensor Dimensions (H х W х D) |
140 х 309 х 203 mm |
Operating temperature | -40 ... + 60 °C |
Average Power Consumption |
30 W |
•Electronics |
1,2 W |
•Heaters |
28,8 W |
Serial Interface |
RS-485 |
Output Data |
Automatic or polled data messages |
Measurement range of MOR |
10 ÷ 10 000 m |
Accuracy |
±10% |
Resolution |
1 m |
Update interval |
3 s |
Averaging time |
1 min, 10 min |
Operating Humidity |
0 ... 100 % |
Sensor Weight | 1.7 kg |
Power Supply | 12 VDC |
Wind speed sensors
Wind direction sensors
Meteorological system video complex

Property |
Description/Value |
Data Chanel |
GPRS / GSM |
Video compression |
Motion JPEG / H.264 |
Frame rate |
25 |
Type |
Color |
Max resolution (DPI) |
800 х 600 (SVGA) |
Lens |
IR-corrected, CS-mount lens, varifocal 3 – 8 mm |
diaphragm DC-iris |
|
Image sensor |
Progressive scan RGB CMOS 1/3” |
Illuminance (lux) |
Color image: 0,1 lux F1,0; |
B/W: 0,02 lux, F1,0; |
|
Data protection |
Password protection, IP addresses filtering system, HTTPS encryption, user access log. |
Operating temperature |
- 40 ... + 50 °C |
Supply voltage |
220V 50 Hz AC, 12V DC |
Road surface temperature sensor
Road surface condition sensor

Surface water solution layer thickness measurement tolerance, mm: +/- (0.05 +0.2 * Vm)
Surface NaCl solution salinity, %: from 0 to 23.00
Surface NaCl solution layer thickness, mm: from 0.1 to 2.00
Surface NaCL solution salinity measurement tolerance, %:
from 0.5% to 10.0% +/- (0.3 * Vm), inclusive
from 10.0% to 20.0% +/- (0.4 * Vm), inclusive
(Vm = measured value).

Property |
Description/Value |
Operating conditions: |
|
- temperature |
- 50 … + 60 °С |
- humidity |
up to 100 % |
Weight |
350 g |
Dimensions |
28 × Ø85 mm |
Precipitation sensor

Detection and measurement of all precipitation types in one sensor.
Unique among its market peers, this sensor is self-cleaning. Each sensor element is installed within an air conduit that maintains sufficient pressure to clear the optical path, eliminating the need for manual clearance of obstructions
Property |
Description/Value |
Number of Precipitation types detection |
4 |
Types of precipitation |
rain, snow, rain with snow, sleet |
Minimum measurable precipitation |
0,2 mm |
Precipitation absolute accuracy |
± (0,1 + 0,08М) mm, where M - measured value of precipitation |
The size of the detected particles of precipitation |
1,0 … 5,0 mm |
Operating conditions: |
|
- temperature |
- 40 … + 50 °С |
- humidity |
Up to 100 % |
Consumption current |
600 mA |
Weight |
4000 g |
Dimensions |
610 × 250 × 250 mm |
Temperature and humidity sensor

Property | Description/Value |
Measurement range temperature |
- 50 … + 50 °С |
Measurement range humidity |
0 … 100 % |
Accuracy over temperature |
± 0,15 °С |
Accuracy over relative humidity | ± 3 % |
Operating conditions: |
|
- temperature |
- 50… + 50 °С |
- relative humidity |
up to 100 % |
Weight |
750 g |
Dimensions |
210 × Ø180 mm |